Victron Skylla-i 24V Charger
A modern and powerful battery charger that withstands the rigors of an adverse environment: heat, humidity and salt air.
- The right amount of charge for a lead-acid battery: variable absorption time
- BatterySafe mode: preventing damage due to excessive gassing
- Storage mode: less maintenance and aging when the battery is not in use
- Smaller and lighter compared to similar models
- NMEA2000 Canbus connection
- PowerControl: set a maximum shore power
- Remote Control
- Li-ion (LiFePo4) ready
Description
Skylla-i (1+1): two outputs to charge 2 battery banks
The Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 3A and with a slightly lower output voltage, is intended to top up a starter battery.
Skylla-i (3): three full current outputs to charge 3 battery banks
TheSkylla-i (3) features 3 isolated outputs. All outputs can supply the full rated output current.
Rugged
Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.
Flexible
Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches, and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities.
Synchronised parallel operation
Several chargers can be connected in parallel and synchronised with help of the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables.
The right amount of charge for a lead-acid battery: variable absorption time
When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge, the absorption time is automatically increased to make sure that the battery is completely recharged.
Preventing damage due to excessive gassing: the BatterySafe mode
In order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP44 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.
Less maintenance and aging when the battery is not in use: the Storage mode
The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mod, float voltage is reduced to 2,2V/cell (26,4V for 24V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.
To increase battery life: temperature compensation
Every Skylla-IP44 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.
Battery voltage sense
In order to compensate for voltage loss due to cable resistance, the Skylla-IP44 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP44 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available.
Additional information
Weight | N/A |
---|---|
Dimensions | N/A |
Model | Skylla-i 24/80(1+1) 230V, Skylla-i 24/80(3) 230V, Skylla-i 24/100(1+1) 230V, Skylla-i 24/100(3) 230V |